第 1/1 張圖片
第 1/1 張圖片
Handbook of Pre-Clinical Continuous Intravenous Infusion, Hardcover by Healin...
US $206.18
大約HK$ 1,605.01
狀況:
很新
狀況完好的書籍。封面發亮且沒有損壞,精裝本書籍含書皮。不存在缺頁或內頁受損,無褶皺或破損,同時也沒有對文字標注/標記,或在留白處書寫內容。內封面上標記極少。書籍的磨損和破損程度也很低。
庫存 2 件
運費:
免費 Economy Shipping.
所在地:Jessup, Maryland, 美國
送達日期:
估計於 10月9日, 三至 10月16日, 三之間送達 運送地點 43230
退貨:
14 日退貨. 由買家支付退貨運費.
保障:
請參閱物品說明或聯絡賣家以取得詳細資料。閱覽全部詳情查看保障詳情
(不符合「eBay 買家保障方案」資格)
物品細節
- 物品狀況
- 很新: 狀況完好的書籍。封面發亮且沒有損壞,精裝本書籍含書皮。不存在缺頁或內頁受損,無褶皺或破損,同時也沒有對文字標注/標記,或在留白處書寫內容。內封面上標記極少。書籍的磨損和破損程度也很低。 查看所有物品狀況定義會在新視窗或分頁中開啟
- Book Title
- Handbook of Pre-Clinical Continuous Intravenous Infusion
- ISBN
- 9780748408672
- Subject Area
- Science, Medical
- Publication Name
- Handbook of Pre-Clinical Continuous Intravenous Infusion
- Publisher
- Taylor & Francis Group
- Item Length
- 10.4 in
- Subject
- Clinical Medicine, Toxicology, Philosophy & Social Aspects, Life Sciences / General, Research
- Publication Year
- 2000
- Type
- Textbook
- Format
- Hardcover
- Language
- English
- Item Height
- 1.1 in
- Item Weight
- 29.8 Oz
- Item Width
- 7.1 in
- Number of Pages
- 344 Pages
關於產品
Product Identifiers
Publisher
Taylor & Francis Group
ISBN-10
0748408673
ISBN-13
9780748408672
eBay Product ID (ePID)
1783195
Product Key Features
Number of Pages
344 Pages
Language
English
Publication Name
Handbook of Pre-Clinical Continuous Intravenous Infusion
Publication Year
2000
Subject
Clinical Medicine, Toxicology, Philosophy & Social Aspects, Life Sciences / General, Research
Type
Textbook
Subject Area
Science, Medical
Format
Hardcover
Dimensions
Item Height
1.1 in
Item Weight
29.8 Oz
Item Length
10.4 in
Item Width
7.1 in
Additional Product Features
Intended Audience
Scholarly & Professional
LCCN
00-037718
Reviews
"...an excellent buy for anyone involved in drug development, risk assessment or within drug licensing agencies and in academic research. ...This book represents a benchmark achievement for this technique ...it will become the standard for many years to come" British Toxicology Society Newsletter
Dewey Edition
21
Illustrated
Yes
Dewey Decimal
615/.6
Table Of Content
Introduction. Femoral Cannulation Using the Jacket/Harness Model in the Rat. Femoral Cannulation Using the Tail Cuff Exteriorisation Method in the Rat. Tethering and the Implanted Button Model in the Rat. Multidose Infusion Toxicity Studies in the Rat. Reproductive Infusion Toxicity Studies in the Rat. Femoral Cannulation Using the Tail Cuff Model in the Mouse. Multidose Infusion Toxicity Studies in the Mouse. Jugular Cannulation and Efficacy Studies in the Mouse. Femoral Cannulation of the Rabbit for Reproductive Toxicity Studies. Jugular Cannulation of the Rabbit for Reproductive Toxicity Studies. Jugular Cannulation of the Dog. The Non-Ambulatory Model in Dog Multidose Infusion Toxicity Studies. The Ambulatory Model in Dog Multidose Infusion Toxicity Studies. Surgical Preparation of the Large Primate. Multidose Infusion Toxicity Studies in the Large Primate. Surgical Preparation and Multidose Infusion Toxicity Studies in the Marmoset. Surgical Preparation of the Mini-Pig. Multidose Infusion Toxicity Studies in the Mini-Pig. Reproductive Toxicity Studies in the Mini-Pig. Common Pathological Findings in Continuous Infusion. The Use of Mini-Osmotic Pumps in Continuous Infusion Studies. The Contribution of Vehicles, Rates of Administration and Volumes to Infusion Studies. Equipment for Continuous Intravenous Infusion. NTI/Sales Copy
Synopsis
Any scientist or technician involved in pre-clinical drug studies knows that infusing animal models with test substances is no simple matter, especially if one wants to do it humanely as well as guarantee results that are not compromised by the procedure. The challenge becomes compounded if one is employing a variety of species. What works for a rat or mouse does not necessarily work for a rabbit or primate. The Handbook of Pre-clinical Continuous Intravenous Infusion answers the needs of researchers and technicians by providing complete instructions for a wide range of infusion techniques delivered to several species. With sections devoted to rats, mice, rabbits, dogs, mini-pigs, and nonhuman primates (both large and small), this thorough text gives step-by-step instructions for the use of a variety of techniques, and equipment. It includes procedures for multidose infusion toxicity and reproductive toxicology studies, and provides guidance on the use of a variety of equipment, including tail cuffs, harnesses, and implanted buttons. It also offers detailed information on surgical preparation for primates and mini-pigs, along with advice about the use of preoperative anesthesia, post surgical analgesics, and antibiotic administration, as well as valuable input on surgical suite design. "... I was amazed and gratified about the level of detail and the practical emphasis on technical expertise and animal well-being. This book is unique in having that as an overt aim." From the Foreword, David B. Morton, University of Birmingham, UK The text concludes with a chapter on general non-species-specific information that discusses common pathological findings in continuous infusion studies, the use of mini-osmatic pumps, and controllable variables such as vehicles, rates of administration and volumes. With contributions from several established experts in the handling of pre-clinical animal models, this authoritative volume removes the need for any guesswork, allowing technicians and researchers to proceed with confidence in undertaking critical studies., Any scientist or technician involved in pre-clinical drug studies knows that infusing animal models with test substances is no simple matter, especially if one wants to do it humanely as well as guarantee results that are not compromised by the procedure. The challenge becomes compounded if one is employing a variety of species. What works for a rat or mouse does not necessarily work for a rabbit or primate. The Handbook of Pre-clinical Continuous Intravenous Infusion answers the needs of researchers and technicians by providing complete instructions for a wide range of infusion techniques delivered to several species. With sections devoted to rats, mice, rabbits, dogs, mini-pigs, and nonhuman primates (both large and small), this thorough text gives step-by-step instructions for the use of a variety of techniques, and equipment. It includes procedures for multidose infusion toxicity and reproductive toxicology studies, and provides guidance on the use of a variety of equipment, including tail cuffs, harnesses, and implanted buttons. It also offers detailed information on surgical preparation for primates and mini-pigs, along with advice about the use of preoperative anesthesia, post surgical analgesics, and antibiotic administration, as well as valuable input on surgical suite design. ..". I was amazed and gratified about the level of detail and the practical emphasis on technical expertise and animal well-being. This book is unique in having that as an overt aim." From the Foreword, David B. Morton, University of Birmingham, UK The text concludes with a chapter on general non-species-specific information that discusses common pathological findings in continuous infusion studies, the use of mini-osmatic pumps, and controllable variables such as vehicles, rates of administration and volumes. With contributions from several established experts in the handling of pre-clinical animal models, this authoritative volume removes the need for any guesswork, allowing technicians and researchers to proceed with confidence in undertaking critical studies., The Handbook of Pre-clinical Continuous Intravenous Infusion answers the needs of researchers and technicians involved with pharmacological testing by providing complete instructions in a single volume reference for a range of infusion techniques delivered to several species.
LC Classification Number
RA1199
賣家提供的物品說明
賣家信用評價 (353,689)
- h***4 (285)- 買家留下的信用評價。過去 1 個月購買已獲認證Thank you!!
- a***m (938)- 買家留下的信用評價。過去 1 個月購買已獲認證Ready great condition. Great book.
- b***g (2333)- 買家留下的信用評價。過去 1 個月購買已獲認證Smooth & easy. The paper stock is a little thin. There’s some “show-through.” And the book wasn’t protected from being dinged up during shipping. Otherwise good.